Measurements
Measurements
This document describes the measurement input specifications required for the Monthly - Home Energy Reports tier.
It defines:
supported measurement metrics
meter types
file structure and upload rules
validation behavior
daily and historical ingestion processes
measurement quality requirements
S3 upload structure
Meter Types
NET2GRID EnergyAI® supports two different categories of measurements:
Mains Meter
Measurements representing the total household energy consumption or production.
Secondary Meter
Measurements representing the consumption or production of a specific appliance or circuit.
Mains Meters
Mains meters represent the total household energy flow.
The supported mains metrics are:
CSDCSRGAS
These measurements are used as the primary input for:
disaggregation
insights
recommendations
NET2GRID EnergyAI® analytics services
Secondary Meters
Secondary meters measure specific appliances or circuits separately from the total household measurements.
These measurements can significantly improve the accuracy of NET2GRID EnergyAI® disaggregation and analytics services, since they provide direct appliance-level ground-truth measurements.
Secondary meter measurements are optional.
Supported Secondary Meter Appliances
The following appliances are currently supported as secondary meters:
Air Condition
air-condition
Electric Vehicle
electric-vehicle
Battery Energy Storage System
battery-energy-storage-system
Heat Pump
heat-pump
Photovoltaic Panels
photovoltaic-panels
Secondary Meter Measurement Types
Secondary meter measurements can be provided using two different approaches:
Dedicated Metering (D)
The appliance is measured through a dedicated meter and its measurements are NOT included in the mains household measurements.
Submetering (S)
The appliance measurements are already included in the mains household measurements.
Dedicated Metering (D)
Dedicated metering is used when a separate physical meter exists for the appliance.
Examples:
dedicated EV charger meter
dedicated heat pump meter
dedicated photovoltaic inverter meter
In this case:
the measurements represent only the appliance
the measurements are independent from the household mains measurements
Submetering (S)
Submetering is used when the appliance measurements are already part of the household mains measurements.
Examples:
appliance-level smart plugs
circuit-level submeters
internally estimated appliance measurements
In this case:
the appliance measurements are included in the mains household measurements
the measurements are used as additional ground-truth information to improve NET2GRID EnergyAI® analytics
Supported Metrics
The following mains metrics are supported:
CSD
Electricity consumption measurements
Yes
CSR
Electricity return-to-grid measurements
Optional
GAS
Gas consumption measurements
Optional
Important Notes
CSRmeasurements are optional when no energy production exists in the household.GASmeasurements are required only when gas-related services are in scope.
Supported Granularity
The following periods of granularities are supported:
15 minutes
60 minutes
This means that a valid daily file typically contains:
60 minutes
24 measurements
15 minutes
96 measurements
Measurement Semantics
The uploaded measurements represent:
timestamped delta energy values
expressed per interval
Measurement values are expected to represent the consumed or produced energy during the interval starting from the provided timestamp until the next interval timestamp.
Supported Units
By default, the expected measurement values are in:
Support for kWh can optionally be enabled through label-partner-specific configuration.
Timezone Requirements
Measurements must represent a complete local installation day.
Each uploaded daily file is expected to contain measurements covering:
in the installation local timezone.
The timestamps inside the file are expected to correspond to this local-day coverage.
Data Exchange
Measurement files are exchanged through AWS S3.
The customer uploads the files into the agreed S3 bucket structure.
Once uploaded:
the files are validated
valid measurements are imported
downstream NET2GRID EnergyAI® processes may be triggered
File Format
Measurement files must:
use CSV format
use UTF-8 encoding without BOM
use comma (
,) as separatoruse dot (
.) as decimal separator
A header row is allowed but not required.
CSV Structure
Each row contains:
Timestamp
UNIX timestamp in milliseconds (UTC)
Value
Delta energy value
Example
Directory Structure
Mains Meter Measurements
Daily Measurements
Path Format
Filename Format
Historical Measurements
Path Format
Filename Format
Secondary Meter Measurements
Secondary Meter Metrics
Secondary meter measurements use interval-based metric identifiers in the following format:
Where:
XXXX
The metric type identifier
PTnHnMnS
The measurement granularity in ISO-8601 duration format
Metric Type Prefixes
0000
Electricity consumption measurements
0001
Electricity production measurements
Granularity Format (PTnHnMnS)
The PTnHnMnS section defines the interval between consecutive measurements.
The format follows the ISO-8601 duration specification:
H
Hours
M
Minutes
S
Seconds
Examples:
60 minutes
PT1H
30 minutes
PT30M
15 minutes
PT15M
Example Secondary Meter Metric IDs
0000-PT15M
Electricity consumption measurements every 15 minutes
0000-PT1H
Electricity consumption measurements every 60 minutes
0001-PT15M
Electricity production measurements every 15 minutes
Supported Granularity
Secondary meter measurements support:
minimum granularity: 15 minutes
maximum granularity: 60 minutes
Only fixed interval measurements are supported.
Daily Measurements
Path Format
Filename Format
Historical Measurements
Path Format
Filename Format
Path and Filename Parameters
bucket_name
The AWS S3 bucket agreed between CUSTOMER and NET2GRID.
labelpartner
The label partner identifier provided by NET2GRID during onboarding.
external-installation-id
Unique identifier of the installation/household.
external-meter-id
Unique identifier of the meter providing the measurements.
date
Measurement date in YYYYMMDD format.
start-date
Start date of the measurements contained in the file, in YYYYMMDD format.
stop-date
End date of the measurements contained in the file, in YYYYMMDD format.
metric
Mains metric identifier (CSD, CSR, GAS).
metric-id
Secondary meter metric identifier in XXXX-PTnHnMnS format.
appliance
Appliance identifier associated with the secondary meter measurements.
source
Measurement source type. D for Dedicated metering. S for Submetering.
unit
Measurement unit.
Measurements Processing
Daily Measurements Process
The daily measurements process is the standard ingestion mechanism used after an installation becomes active.
Daily File Rules
Each uploaded daily file:
must correspond to a single installation
must correspond to a single metric
must correspond to a single day
must not contain measurements from multiple days
must not contain measurements from multiple installations
A separate file is expected for:
each installation
each metric
each day
These rules apply to both:
mains measurements
secondary meter measurements
Daily Validation Process
Every uploaded daily file passes through a validation process before being accepted for downstream processing.
The validation process evaluates:
timestamp consistency
timestamp validity
measurement completeness
invalid or negative values
overall measurement quality
The validation is intended to determine whether the uploaded measurements are suitable for disaggregation and downstream analytics.
Minimum Valid Measurements Threshold
For a file to be considered valid:
at least 75% of the measurements must pass validation checks
If the threshold is satisfied:
the measurements are imported
disaggregation is executed normally
If the threshold is not satisfied:
the measurements are considered invalid
disaggregation is not executed
downstream reports may contain invalid or missing results
Historical Measurements Process
The historical measurements process is intended for the initial onboarding of a new installation.
Historical measurements should be uploaded only once per installation.
Historical Upload Purpose
The historical upload process allows NET2GRID EnergyAI® to:
train the installation models
establish historical energy behavior
generate historical analytics
produce historical Disaggregation Categories reports
Historical File Rules
Unlike daily uploads:
historical files may contain measurements covering multiple days
historical files may contain large continuous periods of measurements
However:
historical uploads are expected to happen only once per installation
After the historical upload process has completed:
all future uploads for the installation must follow the daily upload process and use the
measurementsfoldereven delayed or backfilled measurements must be uploaded through the daily measurements process
These rules apply to both:
mains measurements
secondary meter measurements
Processing Behavior
Measurement files are processed asynchronously after upload.
Measurements Overwrite Behavior
NET2GRID EnergyAI® imports measurements using a last-write-wins approach.
If multiple uploaded files contain measurements for the same installation, metric, and timestamps:
the latest uploaded measurements overwrite previously imported values
This behavior applies to both:
mains measurements
secondary meter measurements
This mechanism allows:
correction of previously uploaded measurements
re-upload of improved-quality data
backfilling of historical periods
Measurement Quality Expectations
The uploaded measurements are expected to:
contain positive values
contain valid timestamps
follow the expected granularity consistently
cover the full expected daily period
contain sufficiently complete data
Poor-quality measurements may lead to:
invalid disaggregation
reduced analytics quality
missing downstream reports
File Processing Reporting
File processing reporting is optional and disabled by default.
It can be enabled upon request by the label partner.
When enabled, NET2GRID publishes processing status messages to an SQS queue after each file is processed.
Processing Report Message Format
filename
Processed filename
timestamp
Processing timestamp
error_code
Processing result code
error_description
Additional processing details
Processing Error Codes
Successful Processing
000
File processed successfully
010
File processed partially
Failed Processing
300
Installation or account not found
400
Validation failure
500
Internal platform error
Permissions
NET2GRID creates the S3 bucket and grants the customer permissions to:
list objects
upload objects
retrieve objects
delete objects
NET2GRID also securely shares the required IAM credentials during onboarding.
Last updated
Was this helpful?